US Chemical Storage buildings can be fitted with several types of doors to provide the necessary access to a client’s hazardous materials while meeting code requirements. Swing Doors and Roll-Up Doors can be applied to any standard model to accommodate any type of container (Drums, Totes, Pallets, Pails, Tanks, etc). Fusible link activated door hold open devices and panic bars are offered for our swing door line also.
60" Double Door
60" Double Door: UL classified and labeled, 3-hour fire rated 60" double leaf door with UL listed self closer. Other constructions and sizes available.
60" Double Door
Double Roll-Up Door
Double Roll-Up Door:  Roll Up Doors, 13'W x 9'H Insulated, 4 Hour Fire Rated, chain operated. Other sizes and constructions available.
Double Roll-Up Door
36 " Single Door
36" Single Door:  UL Classified & labeled, 3 Hour Fire Rated single leaf door with UL listed self closer. Other constructions and sizes available.
36" Single Door
Single Roll-Up Door
Single Roll-Up Door:  Roll Up Doors, 9'W x 7'H Non-Insulated, Non Fire Rated, chain operated. Other sizes and constructions available.
Single Roll-Up Door

Back to Top

Lighting (Click Images to Enlarge)

Lighting in a hazardous material storage building can be a crucial requirement. To meet this, we offer a wide variety of lighting options for each and every safety storage building we manufacture. Explosion Proof and Non Explosion Proof classifications are available for Interior and Exterior Lighting, as well as Emergency Back-Up Lighting.
Explosion Proof Interior Light
Explosion Proof Interior Light:  UL listed Explosion Proof Interior Incandescent Light, Class 1, Div 1 & 2, Groups C & D. Class 2, Div 1 & 2, Groups E,F,G. Class 3, Div 1 & 2
Explosion Proof
Interior Light
Non-Explosion Proof Interior Light
Non-Explosion Proof Interior Light:   UL listed Non-Explosion Proof Interior Incandescent Light. For non-hazardous locations with corrosive fumes, non-combustible dusts and non-explosive vapors and gases.
Non-Explosion Proof
Interior Light
Non-Explosion Proof Exterior Light
Non-Explosion Proof Exterior Light:  UL Listed Weather Proof Incandescent Light with photoelectric switch. To be used in non-harzardous exterior locations.
Non-Explosion Proof
Exterior Light
Explosion Proof Emergency Lighting
Explosion Proof Emergency Lighting:  UL Listed, NEMA 4X Emergency Lights with battery backup. Class 1, Div 2, Groups A,B,C,D. Class 2, Div 2, Groups F&G.
Explosion Proof
Emergency Lighting

Back to Top

Temperature Control (Click Images to Enlarge)

Your hazmat may require specific temperature conditions to maintain the necessarily quality, as well as an intrinsically safe atmosphere. Heating and Cooling are offered in both Explosion Proof and Non Explosion Proof classifications. Refrigeration and Freezing units are available as installed items here at our factory, as well as available for field installations. Each temperature controlled hazmat storage building is also insulated to ensure proper function (R11 and R19 available, as well as special required values).
Explosion Proof Convection Heater
Explosion Proof Convection Heater:  UL Listed Explosion Proof Convection Heater 12,292 BTU/hr with thermostat. Class 1, Division 1 & 2, Groups C & D. Other configurations available.
Explosion Proof
Convection Heater
Explosion Proof Air Conditioner
Explosion Proof Air Conditioner:  UL Listed Explosion Proof Air Conditioner 20,000 BTU/hr with thermostat. Class I, Division 2, Group A,B,C, D. Other configurations available.
Explosion Proof
Air Conditioner
Explosion Proof Refrigeration Unit
Explosion Proof Refrigeration Unit:  UL Listed Explosion Proof Refrigeration Unit 18,700 BTU/hr with thermostat. Class I Div 1, Group D, 208/240V, 1 Phase. Other configurations available.
Explosion Proof
Refrigeration Unit
Explosion Proof Fan Forced Heater
Explosion Proof Fan Forced Heater:  UL Listed Explosion Proof Fan Forced Heater 34,150 BTU/hr with thermostat. Class I, Divisions 1 & 2, Groups C & D. Other configurations available.
Explosion Proof
Fan Forced Heater

Back to Top

Mechanical Ventilation (Click Images to Enlarge)

Fan forced ventilation may be required to due the material being stored, as well as the presence of harmful vapors. We offer Explosion Proof and Non Explosion Proof mechanical ventilation systems to meet this requirement. Fume hoods and Ventilation Thermostats are available also.
Standard Passive Vent
Standard Passive Vent:  Air inlet with fusible link 3 Hour Fire Damper, screened and louvered. Dampers are available for climate controlled buildings. Other configurations available.
Standard Passive Vent
pop-up
Explosion Proof Mechanical Vent:   Explosion Proof Electromechanical Exhaust System. UL Listed, Class I, Division 1, Group C and D enclosed motor. Minimum 6 air changes/hour. Other configurations available.
Explosion Proof
Mechanical Vent
Light Duty Non-Explosion Proof Mechanical Vent
Light Duty Non-Explosion Proof Mechanical Vent:  Non-Explosion Proof Electromechanical Exhaust System. UL Listed. 3 speed dial controller. Minimum 6 air changes/hour. Other configurations available.
Light Duty Non-Explosion Proof Mechanical Vent
Class B Explosion Proof Mechanical Vent
Class B Explosion Proof Mechanical Vent:  Explosion Proof Fan Forced Ventilation Fan. UL Listed Class 1, Div 1 Group B enclosed motor. Minimum 6 air changes/hour. Other configurations available.
Class B Explosion Proof
Mechanical Vent

Back to Top

Fire Suppression (Click Images to Enlarge)

Many building codes and other requirements call for some sort of fire suppression for chemical storage buildings. As a result, we offer this suppression in several forms to meet your individual requirements. Water Sprinkler Systems, Dry Chemical Systems, Foam and CO2 Systems can all be installed on our buildings by our personnel, or a specialist at the point of location. Audible and visual alarms are available for these systems. Manual pull stations and other fire suppression accessories are available, as well.
Dry Chemical Fire Suppression System (Open)
Dry Chemical Fire Suppression System (Open):  Dry Chemical Fire Suppression System for class A,B, C fires. UL, ULC Listed and FM Approved. Audible alarm included, remote contact available. Fusible link activated.
Dry Chemical Fire Suppression System (Open)
Dry Chemical Fire Suppression System (Closed)
Dry Chemical Fire Suppression System (Closed):  Self-contained Dry Chemical Fire Suppression system with manual pull station, audible alarm and available contact for remote annunciation. Fusible link activated.
Dry Chemical Fire Suppression System (Closed)
Dry Chemical Fire Suppression Head
Dry Chemical Fire Suppression Head:  Dry Chemical Fire Suppression Nozzle shown. Compliantly installed, fusible link activated. Covers provided. Other types of fire suppression available.
Dry Chemical Fire Suppression Head
Water Sprinkler Head
Water Sprinkler Head:  UL Listed and FM approved Sprinkler Heads for Water Sprinkler Piping Assembly with 1-1/2" NPT Exterior Coupling with Cap. Other types of fire suppression available.
Water Sprinkler Head

Back to Top

Spill Detection (Click Images to Enlarge)

The secondary containment (or sump) of each building catches any spills compliantly per all applicable regulations. Spill detection is offered for each model in Explosion Proof and Non Explosion Proof with audible or visual alarms, as well as available contacts for coordinating with an on-site alarm system. These devices are located within the spill containment area to notify of any detection immediately.
Explosion Proof Liquid Level Detector
Explosion Proof Liquid Level Detector:  Explosion Proof UL Listed, Class I, Groups A,B,C & D, Division 1, Liquid Level Detector. Audible, Visual and Remote Annunciation available.
Explosion Proof
Liquid Level Detector
Non-Explosion Proof Liquid Level Detector
Non-Explosion Proof Liquid Level Detector:  Non-Explosion Proof Liquid Level Detector. Audible, Visual and Remote Annunciation available
Non-Explosion Proof
Liquid Level Detector
   

Back to Top

Sensors (Click Images to Enlarge)

Gas sensors and smoke detectors are offered in both Explosion Proof and Non Explosion Proof classifications for any type of material specified. Each can be equipped with visual and audible alarms, as well as provide contacts for any local alarms.
Explosion Proof Gas Sensor
Explosion Proof Gas Sensor:  Explosion Proof Gas Sensor with Calibration Kit. Class 1 Div 1 Groups A,B,C & D. Provided for any stored gas.
Explosion Proof Gas Sensor
Explosion Proof Gas Sensor Transmitter
Explosion Proof Gas Sensor Transmitter:  Explosion Proof Gas Sensor Transmitter. Class 1 Div 1 Groups A,B,C & D. Other configurations available.
Explosion Proof Gas
Sensor Transmitter
Non-Explosion Proof Gas Sensor Transmitter
Non-Explosion Proof Gas Sensor Transmitter:  Transmitter/controller with local digital display, dual level audio/visual alarm indicators. Explosion Proof configurations also available.
Non-Explosion Proof Gas Sensor Transmitter
Explosion Proof Gas Sensor Display
Explosion Proof Gas Sensor Display:  Explosion Proof Gas Sensor Display. Class 1 Div 1 Groups A,B,C & D. Other configurations available.
Explosion Proof Gas
Sensor Display

Back to Top

Electrical Accessories (Click Images to Enlarge)

Interior and Exterior outlets and switches are available in both Explosion Proof and Non Explosion Proof classifications. Electrical Load Centers, Transformers and Junction Boxes are also available in the same styles.
Interior Explosion Proof Duplex Outlet
Interior Explosion Proof Duplex Outlet:  UL Listed Explosion-Proof Duplex Outlet, 125V, 20A, rated for Class I, Division I, Groups C & D Hazardous Locations.
Interior Explosion Proof Duplex Outlet
Exterior Non Explosion Proof Duplex Outlet
Exterior Non Explosion Proof Duplex Outlet:  Weatherproof, UL Listed 20 amp, 120 VAC, GFCI Duplex Receptacle with cover. Other configurations available.
Exterior Non Explosion Proof Duplex Outlet
Electrical Load Center with Transformer
Electrical Load Center with Transformer:  UL Listed, Single-Phase, 3 Wire, 120/240V 100 A Load Center (NEMA 3R) with Transformer. Other configurations available.
Electrical Load Center
with Transformer
Explosion Proof Switches
Explosion Proof Switches:  UL Listed Explosion-proof snap-type switch rated for Class I, Division I, Groups C & D hazardous locations.
Explosion Proof Switches

Back to Top

Shelving (Click Images to Enlarge)

Shelving can be applied to any of our buildings to accommodate storage of materials without occupying crucial floor space. Our shelves are constructed with a 2” lip to create leak-proof spill containment at that level. This shelving is available in galvanized steel, as well as stainless steel. Other materials are available upon request.
Galvanized Steel Sump Shelving
Galvanized Steel Sump Shelving:  Adjustable 16" wide, leak-proof steel shelving formed and welded from heavy gauge steel with a 2" lip around the entire shelf. Multiple tiers available.
Galvanized Steel Sump Shelving
Stainless Steel Sump Shelving
Stainless Steel Sump Shelving:  Adjustable 16" leak-proof, heavy duty stainless steel shelving formed and welded with a 2" lip around the entire shelf. Multiple tiers available.
Stainless Steel Sump Shelving
   

Back to Top

Explosion Relief Construction (Click Images to Enlarge)

Explosion Relief is offered in each construction we manufacture (Non Fire Rated, 2-Hour Fire Rated and 4-Hour Fire Rated), as well as each size we build. This construction is designed to meet either FM or NFPA requirements.
Explosion Relief Panel
Explosion Relief Panel:  Pressure-relief panel designed to release at an internal pressure of 20 psf. Open vent area is 1 sq. ft. per 50 cu. Ft. of interior volume.
Explosion Relief Panel
Exterior View Explosion Relief Panel
Exterior View Explosion Relief Panel:  Pressure-relief panel with Factory Mutual approved release fasteners. Meets ASTM-D35, ASTM-E84, ASTM-E-283 & FM. Approval Standard Class Number 6049.
Exterior View Explosion Relief Panel
   

Back to Top

Partition Walls (Click Images to Enlarge)

Separation walls are provided for the purpose of segregating non-compatible materials. These walls are solid partitions from ceiling to the floor of the secondary containment. Open mesh walls can be provided for the sake of separating inventory, as well as security. Entry doors can be provided in these walls if needed.
4-Hour Fire Rated Partition Wall
4-Hour Fire Rated Partition Wall:  4 Hour Fire-Rated, bi-directional partition wall, with sump separator. Non and 2 Hour Fire Rated construction also available.
4-Hour Fire Rated
Partition Wall
4-Hour Fire Rated Partition Wallp
4-Hour Fire Rated Partition Wall:  4 hour fire-rated, bi-directional partition wall fabricated from UL Classified fire-resistive gypsum wallboard. Non and 2 Hour Fire Rated construction also available.
4-Hour Fire Rated
Partition Wall
Open Mesh Partition Wall
Open Mesh Partition Wall:  Security separation wall. Galvanized wire mesh to allow air movement between compartments. Sump separator available.
Open Mesh Partition Wall
 

Back to Top

Racks (Click Images to Enlarge)

US Chemical Storage offers racks to support and securall pallets, totes, cylinders and other containers. Pallet and tote racking allows for 1 or 2 level storage in multiples to provide maximized storage space. Cylinder racks are provided as designed/specified for each situation, and can be customized in both size and style.
Tote/Pallet Racks
Tote/Pallet Racks:  Industrial gauge tubular steel rack designed for 5,600lb load per pallet. Custom sizes and configurations available.
Tote/Pallet Racks
Sliding Tote/Pallet Rack
Sliding Tote/Pallet Rack:  Racking utilizes a system of enveloping carts installed into high density storage rack. Constructed of 100% structural steel.
Sliding Tote/Pallet Rack
Gas Cylinder Rack
Gas Cylinder Rack:  Gas Cylinder Rack constructed of structural steel to support the vertical storage of cylinders. Custom sizes and configurations available.
Gas Cylinder Rack
Gas Cylinder Rack
Gas Cylinder Rack:  Gas Cylinder Rack constructed to custom designs to fit cylinders. Chains provided for stability of stored materials.
Gas Cylinder Rack

Back to Top

Flooring (Click Images to Enlarge)

The secondary containment area built into our buildings is typically covered with open grating to allow spills to flow in the containment area. This flooring can be offered in galvanized steel, aluminum, and fiberglass materials. Custom flooring can also be offered if a different type of surface is needed. When storing cylinders or other non-liquid materials, the secondary containment can be removed to provide a flat floor surface.
Steel Grate Flooring
Steel Grate Flooring:  Galvanized steel floor grating fabricated from welded steel grating. Floor System is fabricated to comply with NAAMM MBG 531.
Steel Grate Flooring
Pultruded T-bar Fiberglass Flooring
Pultruded T-bar Fiberglass Flooring:  Pultruded T-Bar Fiberglass Floor Grating made with Fire-Retardant Vinylester Resin, Corrosion and Ultraviolet (UV) Resistant.
Pultruded T-bar
Fiberglass Flooring
Gravity Roller Flooring
Gravity Roller Flooring:  Light duty gravity roller conveyor, 24" wide x 10' Long section. Maximum distributed live load per foot is 620 Lbs.
Gravity Roller Flooring
Gravity Roller Flooring
Gravity Roller Flooring:  Heavy duty gravity roller conveyor, 28" wide x 10' long section. Maximum distributed live load per foot is 1620 Lbs.
Gravity Roller Flooring

Back to Top

Ramps (Click Images to Enlarge)

A full line of ramps (light duty and heavy duty) is offered for each model manufactured. These ramps can be fitted with safety rails or raised edges, and provide a non-slip surface.
Standard Loading Ramp
Standard Loading Ramp:  Access Ramp (44"W x 88"L) fabricated from 12 gauge steel. Rated for 275 lbs. per sq. ft. Custom sizes available.
Standard Loading Ramp
pop-up
Heavy Duty Loading Ramp:  Access Ramp (48"W x 88"L) fabricated from 3/16" diamond plate steel. Rated for 500 lbs. per sq. ft. Custom sizes available.
Heavy Duty Loading Ramp
Loading Ramp in Place
Loading Ramp in Place:  Access ramp (54"W x 88"L) fabricated from 12 gauge steel. Rated for 275 lbs. per sq. ft. Custom sizes available.
Loading Ramp in Place
 

Back to Top

Personal Safety (Click Images to Enlarge)

A crucial aspect of working with hazardous materials is personal safety. Eyewash and Shower items are offered in our accessory line to provide a safe working environment around your haz-mat. Custom accessories can be provided as specified and needed.
Fixed Eyewash Station
Fixed Eyewash Station:  ABS Plastic Bowl Mounted on 1-1/4" Galvanized Pipe with 9" Diameter Floor Flange. Meets ANSI Standard Z358.1-1981.
Fixed Eyewash Station
Interior Eyewash/Shower Combination
Interior Eyewash/Shower Combination:  Drench Shower and Eyewash Fountain with 2 Heads. Furnished with Galvanized Intermediate Pipe and Fittings. Meets ANSI Standard Z358.1-1981.
Interior Eyewash/Shower Combination
Exterior Eyewash/Shower Combination
Exterior Eyewash/Shower Combination:  Drench Shower and Eyewash Fountain with 2 Heads, with 9" Floor Mounting Flange and High Impact Plastic Bowl. Meets ANSI Standard Z358.1-1981.
Exterior Eyewash/Shower Combination
Portable Eyewash Station
Portable Eyewash Station:  Sixteen-Gallon High Impact Polyethylene Construction Provides 15 Minutes of Continuous Flow. Meets ANSI Standard Z358.1-1981.
Portable Eyewash Station

Back to Top

Custom Accessories (Click Images to Enlarge)

Drum Crane/Hoists - Gravity Roller Flooring - Piped Sleeve Penetrations - Fume Hoods
Floorless Construction - Sinks - Stall Showers - Grounding Buss Bar / Rings
Gravity Roller Flooring with Fume Hood
Gravity Roller Flooring with Fume Hood:  Heavy duty gravity roller flooring installed to provide optimum access to the shown Explosion Proof Fume Hood Exhaust System. Custom configurations available.
Gravity Roller Flooring with Fume Hood
Assorted Explosion Proof Accessories
Assorted Explosion Proof Accessories:  Shelving, Explosion Proof Lighting and Exit Lighting with Battery Backup, Explosion Proof Air Conditioner and Heater, and Stainless Steel Sink Shown. Other accessories available.
Assorted Explosion Proof Accessories
pop-up
Drum Crane/Hoist:  Drum Crane and Hoist (manual) installed for easy movement of drums throughout building’s interior. Electric systems (EP and Non EP) available.
Drum Crane/Hoist
Grounding Buss Bar
Grounding Buss Bar:  Copper Buss Bar installed on interior walls of building for static grounding. Buss Bar is ¼” thick and 1” wide. Custom configurations available.
Grounding Buss Bar
Stall Shower and Sink
Stall Shower and Sink:  Free Standing Neo-Angle Corner Shower with Wall-Mounted Utility Porcelain Sink. Installed for use by personnel in remote location. Other custom configurations available.
Stall Shower and Sink
Custom Floor
Custom Floor:  Square Molded Fiberglass Floor Grating with open area for installation of liquid storage tank. Secondary containment provided to meet required capacity.
Custom Floor
   